MicroFiber Glass Fiber Pipe Insulation, Pre-formed Pipe Type
Price 85.00 บาท – 977.00 บาทPrice range: 85.00 บาท through 977.00 บาท
Product Details
MicroCover glass fiber insulation is designed for hot pipes with temperatures up to 450°C. It maintains heat within pipes and protects workers from direct contact with heat.
MicroCover products are straight tubes with a central hole to fit steel or copper pipes. Each section is 1 meter long for easy pipe length calculation.
MicroCover
MicroCover glass fiber insulation is designed for hot pipes with temperatures up to 450°C to retain heat within pipes and protect workers from direct contact with hot surfaces. MicroCover products are straight tubes with a center hole that fits steel or copper pipes. Each section is 1 meter long for easy pipe length calculation.
Operating Temperature
MicroCover glass fiber insulation has a wide operating temperature range of -18°C to 450°C. It’s typically used for high-temperature applications due to its relatively stable thermal conductivity at higher temperatures.
Thermal conductivity
Thermal conductivity is crucial for hot water pipe insulation. Lower thermal conductivity means thinner insulation can be used, reducing product cost. Glass fiber insulation is suitable for pipes below 450°C due to its low and stable thermal conductivity.
MicroCover Thermal Conductivity Table
|
Hot Surface (°C) |
Cold Surface (°C) |
Mean Temperature (°C) |
Apparent Thermal Conductivity (W/m·K) |
|
55.60 |
20.48 |
38.04 |
0.03246 |
|
134.58 |
24.11 |
79.35 |
0.03697 |
|
213.25 |
28.12 |
120.69 |
0.04146 |
|
293.95 |
33.08 |
163.52 |
0.04727 |
|
374.69 |
38.60 |
206.65 |
0.05456 |
|
454.33 |
44.83 |
249.58 |
0.06356 |
Water Vapor Permeability
Water or vapor permeability is crucial in hot pipe systems. After insulating pipes, a jacket is installed to protect the insulation and prevent water or rain damage.
If the jacket leaks and water penetrates to the pipe surface, steel pipes can develop red rust when exposed to water and moisture. If left untreated, this can lead to corrosion over time.
Glass fiber insulation for pipe systems incorporates innovations to prevent water penetration. When rain falls or water drips on the insulation, it forms droplets on the surface, similar to a car windshield coating in rain. The water doesn’t adhere to the surface and evaporates naturally.
Insulation Thickness Selection Guide
MicroFiber insulation manufacturers have designed this table for quick and convenient insulation thickness selection:
Economically Appropriate Insulation Thickness
|
Pipe System |
Fluid Temperature Range |
Pipe Size |
||||
|
< 1″ (< 33 mm) |
1.5″ – 2″
(42 – 60 mm) |
2.5″ – 4″
(73 – 114 mm) |
5″ – 6″
(140 – 168 mm) |
8″ – 12″ (219 – 324 mm) |
||
| Hot Pipes (Steam, Hot water) |
152 – 238 |
|||||
| High Pressure |
1.5″ (38mm) |
1.5″ (38mm) | 2″ (50 mm) | 2.5″ (63 mm) |
3″ (75 mm) |
|
| Medium Pressure |
122 – 151 |
1.5″ (38mm) |
1.5″ (38mm) | 2″ (50 mm) | 2″ (50 mm) |
2.5″ (63 mm) |
| Low Pressure |
94 – 121 |
1″ (25 mm) |
1.5″ (38mm) | 1.5″ (38mm) | 2″ (50 mm) |
2″ (50 mm) |
| Low Temperature |
49 – 93 |
1″ (25 mm) |
1″ (25 mm) | 1.5″ (38mm) | 1.5″ (38mm) |
1.5″ (38mm) |
| Condensate |
30 – 50 |
1″ (25 mm) |
1″ (25 mm) | 1″ (25 mm) | 1.5″ (38mm) |
1.5″ (38mm) |
Product Size Table
|
Pipe Size (NPS) |
Internal Diameter of Pipe Insulation |
Insulation Thickness (mm) |
|
0.5 |
22 |
25, 38, 50, 63, 75, 100 |
|
0.75 |
27 |
25, 38, 50, 63, 75, 100 |
|
1 |
34 |
25, 38, 50, 63, 75, 100 |
|
1.25 |
43 |
25, 38, 50, 63, 75, 100 |
|
1.5 |
49 |
25, 38, 50, 63, 75, 100 |
|
2 |
61 |
25, 38, 50, 63, 75, 100 |
|
2.5 |
74 |
25, 38, 50, 63, 75, 100 |
|
3 |
90 |
25, 38, 50, 63, 75, 100 |
|
3.5 |
102 |
25, 38, 50, 63, 75, 100 |
|
4 |
115 |
25, 38, 50, 63, 75, 100 |
|
4.5 |
128 |
25, 38, 50, 63, 75, 100 |
|
5 |
143 |
25, 38, 50, 63, 75, 100 |
|
6 |
170 |
25, 38, 50, 63, 75, 100 |
|
7 |
196 |
25, 38, 50, 63, 75, 100 |
|
8 |
221 |
25, 38, 50, 63, 75, 100 |
|
9 |
246 |
25, 38, 50, 63, 75, 100 |
|
10 |
275 |
25, 38, 50, 63, 75, 100 |
|
12 |
324 |
25, 38, 50, 63, 75, 100 |
Technical Data Table
|
Features |
MicroCover |
Test Standard |
|
Operating Temperature |
-18°C – 450°C |
ASTM C 411 |
|
Maximum Surface Temperature |
-20°C – 116°C |
ASTM C 1136 |
|
Density |
64 kg/m³ |
|
|
Water Vapor Absorption |
< 1.0% at 49°C, 95% RH |
ASTM C1104 |
|
Mold and Fungus Growth |
Does not promote mold and fungus growth |
ASTM C665 |
|
Surface Burning Characteristics |
Flame Spread < 25 Smoke Development < 50 |
ASTM E84 |