{"id":45596,"date":"2022-12-02T13:16:33","date_gmt":"2022-12-02T06:16:33","guid":{"rendered":"https:\/\/3t-insulation.com\/scg-glass-wool-insulation-for-air-conditioning-systems-double-sided-foil-model-frkf-g\/"},"modified":"2022-12-02T13:16:33","modified_gmt":"2022-12-02T05:16:33","slug":"scg-glass-wool-insulation-for-air-conditioning-systems-double-sided-foil-model-frkf-g","status":"publish","type":"product","link":"https:\/\/3t-insulation.com\/en\/product\/scg-glass-wool-insulation-for-air-conditioning-systems-double-sided-foil-model-frkf-g\/","title":{"rendered":"SCG Glass Wool Insulation for Air Conditioning Systems, Double-sided Foil, Model FRKF-G"},"content":{"rendered":"<h2>SCG Glass Wool Insulation for Air Conditioning Systems<\/h2>\n<h3>Duct insulation work<\/h3>\n<p style=\"padding-left: 40px;\">Large air conditioning systems consisting of chillers and Air Handling Units (AHU) require galvanized ductwork to distribute cool air to desired points. To maintain the temperature of the cool air, we must insulate the ducts to prevent cold air from escaping. This also helps reduce noise transmission. Typically, glass wool insulation with a density of 24 kg\/m\u00b3 and thickness of 1&#8243; (25 mm) or 2&#8243; (50 mm) is used, depending on requirements and installation space.<\/p>\n<h3>Product List<\/h3>\n<p style=\"padding-left: 40px;\"><strong>FRK-G<\/strong><\/p>\n<p style=\"padding-left: 40px;\">SCG thermal insulation for air conditioning systems, FRK-G model for duct insulation, covered with 3-way reinforced aluminum foil, non-flammable on one side, tested according to BS 476 and ASTM E84 standards<\/p>\n<p style=\"padding-left: 40px;\"><strong>FRKF-G<\/strong><\/p>\n<p style=\"padding-left: 40px;\">SCG thermal insulation for air conditioning systems, FRKF-G model for duct insulation, covered with 3-way reinforced aluminum foil, non-flammable on both sides, tested according to BS 476 and ASTM E83 standards<\/p>\n<table style=\"height: 675px;\" width=\"888\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\">\n<p style=\"text-align: center;\">Density (kg\/m\u00b3)<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">Thickness (mm.)<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">Size<br \/>\n (W x L)<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">Thermal conductivity (K-value)<br \/>\nW\/m.K<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p style=\"text-align: center;\">16<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">25<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">1.22 x 30.50<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">0.038<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p style=\"text-align: center;\">16<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">38<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">1.22 x 30.50<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">0.038<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p style=\"text-align: center;\">16<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">50<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">1.22 x 15.25<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">0.035<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p style=\"text-align: center;\">24<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">25<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">1.22 x 30.50<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">0.035<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p style=\"text-align: center;\">24<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">38<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">1.22 x 15.25<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">0.035<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p style=\"text-align: center;\">24<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">50<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">1.22 x 15.25<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">0.035<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p style=\"text-align: center;\">32<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">25<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">1.22 x 15.25<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">0.033<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p style=\"text-align: center;\">32<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">38<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">1.22 x 15.25<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">0.033<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p style=\"text-align: center;\">32<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">50<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">1.22 x 15.25<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">0.033<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p style=\"text-align: center;\">48<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">25<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">1.22 x 7.50<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">0.033<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Installation Guidelines<\/h3>\n<ol>\n<li>Duct surfaces must be clean, dry, free of rust, oil residue, and leaks. Test for leaks at all points before insulating.<\/li>\n<li>Cut insulation to specified size, trimming 50 mm from the edges while leaving the facing material as a flap to overlap insulation joints.\n<p><div id=\"attachment_22855\" style=\"width: 730px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/3t-insulation.com\/product\/attachment\/duct_technical_2\/\" rel=\"attachment wp-att-22855\"><img decoding=\"async\" aria-describedby=\"caption-attachment-22855\" class=\"lazyload size-full wp-image-22855\" src=\"https:\/\/3t-insulation.com\/wp-content\/uploads\/2022\/05\/duct_technical_2.png\" data-orig-src=\"https:\/\/3t-insulation.com\/wp-content\/uploads\/2022\/05\/duct_technical_2.png\" alt=\"DUCT COVER WITH INSULATION\" width=\"720\" height=\"400\" title=\"|\" srcset=\"data:image\/svg+xml,%3Csvg%20xmlns%3D%27http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%27%20width%3D%27720%27%20height%3D%27400%27%20viewBox%3D%270%200%20720%20400%27%3E%3Crect%20width%3D%27720%27%20height%3D%27400%27%20fill-opacity%3D%220%22%2F%3E%3C%2Fsvg%3E\" data-srcset=\"https:\/\/3t-insulation.com\/wp-content\/uploads\/2022\/05\/duct_technical_2-200x111.png 200w, https:\/\/3t-insulation.com\/wp-content\/uploads\/2022\/05\/duct_technical_2-350x194.png 350w, https:\/\/3t-insulation.com\/wp-content\/uploads\/2022\/05\/duct_technical_2-400x222.png 400w, https:\/\/3t-insulation.com\/wp-content\/uploads\/2022\/05\/duct_technical_2-500x278.png 500w, https:\/\/3t-insulation.com\/wp-content\/uploads\/2022\/05\/duct_technical_2-600x333.png 600w, https:\/\/3t-insulation.com\/wp-content\/uploads\/2022\/05\/duct_technical_2-700x389.png 700w, https:\/\/3t-insulation.com\/wp-content\/uploads\/2022\/05\/duct_technical_2.png 720w\" data-sizes=\"auto\" data-orig-sizes=\"(max-width: 720px) 100vw, 720px\" \/><\/a><p id=\"caption-attachment-22855\" class=\"wp-caption-text\">Method for cutting glass wool insulation for duct covering<\/p><\/div><\/li>\n<li>Wrap insulation around the duct with tight joints. Overlap the flap onto the other end of the insulation and use aluminum foil tape (2.5&#8243; or wider) to seal all insulation joints.\n<div class=\"mceTemp\"><\/div>\n<p><div id=\"attachment_22856\" style=\"width: 730px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/3t-insulation.com\/product\/attachment\/duct_technical\/\" rel=\"attachment wp-att-22856\"><img decoding=\"async\" aria-describedby=\"caption-attachment-22856\" class=\"lazyload size-full wp-image-22856\" src=\"https:\/\/3t-insulation.com\/wp-content\/uploads\/2022\/05\/duct_technical.png\" data-orig-src=\"https:\/\/3t-insulation.com\/wp-content\/uploads\/2022\/05\/duct_technical.png\" alt=\"DUCT TECHNICAL\" width=\"720\" height=\"400\" title=\"|\" srcset=\"data:image\/svg+xml,%3Csvg%20xmlns%3D%27http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%27%20width%3D%27720%27%20height%3D%27400%27%20viewBox%3D%270%200%20720%20400%27%3E%3Crect%20width%3D%27720%27%20height%3D%27400%27%20fill-opacity%3D%220%22%2F%3E%3C%2Fsvg%3E\" data-srcset=\"https:\/\/3t-insulation.com\/wp-content\/uploads\/2022\/05\/duct_technical-200x111.png 200w, https:\/\/3t-insulation.com\/wp-content\/uploads\/2022\/05\/duct_technical-350x194.png 350w, https:\/\/3t-insulation.com\/wp-content\/uploads\/2022\/05\/duct_technical-400x222.png 400w, https:\/\/3t-insulation.com\/wp-content\/uploads\/2022\/05\/duct_technical-500x278.png 500w, https:\/\/3t-insulation.com\/wp-content\/uploads\/2022\/05\/duct_technical-600x333.png 600w, https:\/\/3t-insulation.com\/wp-content\/uploads\/2022\/05\/duct_technical-700x389.png 700w, https:\/\/3t-insulation.com\/wp-content\/uploads\/2022\/05\/duct_technical.png 720w\" data-sizes=\"auto\" data-orig-sizes=\"(max-width: 720px) 100vw, 720px\" \/><\/a><p id=\"caption-attachment-22856\" class=\"wp-caption-text\">Glass wool duct insulation installation<\/p><\/div><\/li>\n<li>For ducts wider than 24&#8243;, use fasteners to secure insulation to the duct surface, attaching them to the bottom of the duct at intervals not exceeding 18&#8243;.<\/li>\n<li>Inspect the facing material. If leaks, abrasions, or tears are found, cover with aluminum foil tape to prevent moisture and vapor accumulation in the insulation.<\/li>\n<\/ol>\n<table style=\"height: 328px;\" width=\"1049\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\">\n<p style=\"text-align: center;\">Standard Thickness<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">Average Installed Thickness<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">Round Duct<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">Square Duct<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">Rectangular Duct<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p style=\"text-align: center;\">1&#8243; (25 mm)<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">3\/4&#8243; (19 mm)<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">P+7&#8243; (178 mm)<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">P+6&#8243; (152 mm)<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">P+5&#8243; (127 mm)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p style=\"text-align: center;\">1-1\/2&#8243; (38 mm)<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">1-1\/8&#8243; (28 mm)<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">P+9-1\/2&#8243; (241 mm)<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">P+8&#8243; (203 mm)<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">P+7&#8243; (178 mm)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p style=\"text-align: center;\">2&#8243; (51 mm)<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">1-1\/2&#8243; (38 mm)<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">P+12&#8243; (305 mm)<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">P+10&#8243; (254 mm)<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">P+8&#8243; (203 mm)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p style=\"text-align: center;\">2.2&#8243; (56 mm)<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">1.65&#8243; (42 mm)<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">P+13&#8243; (330 mm)<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">P+11&#8243; (279 mm)<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">P+8-1\/2&#8243; (279 mm)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p style=\"text-align: center;\">3&#8243; (76 mm)<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">2-1\/4&#8243; (57 mm)<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">P+17&#8243; (432 mm)<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">P+14-1\/2&#8243; (368 mm)<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">P+11-1\/2&#8243; (292 mm)<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"text-align: left;\"><strong>Technical Data Table<\/strong><\/p>\n<table style=\"height: 257px;\" width=\"837\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\">\n<p style=\"text-align: center;\">Features<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">Technical Specifications<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">Test Standard<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p style=\"text-align: center;\">Water Vapor Absorption<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">0.2 % by volume<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">ASTM C1104<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Mold and Fungus Growth<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">Does not promote mold and fungus growth<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">ASTM C665<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Surface Burning on Insulation<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">Flame Spread &lt; \u2264 25<br \/>\n, Smoke Develop &lt; \u2264 50<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">ASTM E84<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>SCG thermal insulation for air conditioning systems, FRKF-G model for duct insulation, covered with 3-way reinforced aluminum foil, non-flammable on both sides, tested according to BS 476 and ASTM E83 standards<\/p>\n","protected":false},"featured_media":22861,"template":"","meta":[],"product_brand":[506],"product_cat":[647],"product_tag":[],"class_list":{"0":"post-45596","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-scg","7":"product_cat-cold-air-duct-insulation","9":"first","10":"onbackorder","11":"shipping-taxable","12":"product-type-variable"},"_links":{"self":[{"href":"https:\/\/3t-insulation.com\/en\/wp-json\/wp\/v2\/product\/45596","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/3t-insulation.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/3t-insulation.com\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/3t-insulation.com\/en\/wp-json\/wp\/v2\/media\/22861"}],"wp:attachment":[{"href":"https:\/\/3t-insulation.com\/en\/wp-json\/wp\/v2\/media?parent=45596"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/3t-insulation.com\/en\/wp-json\/wp\/v2\/product_brand?post=45596"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/3t-insulation.com\/en\/wp-json\/wp\/v2\/product_cat?post=45596"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/3t-insulation.com\/en\/wp-json\/wp\/v2\/product_tag?post=45596"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}