{"id":39153,"date":"2022-12-02T13:17:55","date_gmt":"2022-12-02T06:17:55","guid":{"rendered":"https:\/\/3t-insulation.com\/scg-glass-wool-insulation-for-air-conditioning-systems-single-sided-foil-frk-g-model\/"},"modified":"2022-12-02T13:17:55","modified_gmt":"2022-12-02T05:17:55","slug":"scg-glass-wool-insulation-for-air-conditioning-systems-single-sided-foil-frk-g-model","status":"publish","type":"product","link":"https:\/\/3t-insulation.com\/en\/product\/scg-glass-wool-insulation-for-air-conditioning-systems-single-sided-foil-frk-g-model\/","title":{"rendered":"SCG Glass Wool Insulation for Air Conditioning Systems, Single-sided Foil FRK-G Model"},"content":{"rendered":"<h2>SCG Glass Wool Insulation for Air Conditioning Systems<\/h2>\n<h3>Duct Insulation Work<\/h3>\n<p style=\"padding-left: 40px;\">Large air conditioning systems consisting of chillers and Air Handling Units (AHU) require galvanized air ducts to distribute cool air to desired points. To maintain air temperature, heat insulation must be installed to prevent cold air leakage. It also provides soundproofing benefits. Typically, glass wool insulation used in air conditioning duct systems has a density of 24 kg\/m\u00b3, with thickness options of 1 inch (25 mm) or 2 inches (50 mm), depending on requirements and installation space.<\/p>\n<h3>Product List<\/h3>\n<p style=\"padding-left: 40px;\"><strong>FRK-G<\/strong><\/p>\n<p style=\"padding-left: 40px;\">SCG thermal insulation for air conditioning systems, FRK-G model duct insulation with single-sided fire-retardant tri-directional reinforced aluminum foil, tested to BS 476 and ASTM E84 standards<\/p>\n<p style=\"padding-left: 40px;\"><strong>FRKF-G<\/strong><\/p>\n<p style=\"padding-left: 40px;\">SCG thermal insulation for air conditioning systems, FRKF-G model duct insulation with double-sided fire-retardant tri-directional reinforced aluminum foil, tested to BS 476 and ASTM E83 standards<\/p>\n<table style=\"height: 675px;\" width=\"888\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\">\n<p style=\"text-align: center;\">Density (kg\/m\u00b3)<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">Thickness (mm.)<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">Size<br \/>\n (W x L)<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">Thermal Conductivity (K-value)<br \/>\n W\/m.K<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p style=\"text-align: center;\">16<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">25<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">1.22 x 30.50<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">0.038<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p style=\"text-align: center;\">16<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">38<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">1.22 x 30.50<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">0.038<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p style=\"text-align: center;\">16<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">50<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">1.22 x 15.25<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">0.035<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p style=\"text-align: center;\">24<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">25<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">1.22 x 30.50<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">0.035<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p style=\"text-align: center;\">24<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">38<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">1.22 x 15.25<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">0.035<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p style=\"text-align: center;\">24<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">50<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">1.22 x 15.25<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">0.035<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p style=\"text-align: center;\">32<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">25<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">1.22 x 15.25<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">0.033<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p style=\"text-align: center;\">32<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">38<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">1.22 x 15.25<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">0.033<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p style=\"text-align: center;\">32<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">50<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">1.22 x 15.25<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">0.033<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p style=\"text-align: center;\">48<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">25<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">1.22 x 7.50<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">0.033<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Installation Guidelines<\/h3>\n<ol>\n<li>Duct surfaces must be clean, dry, rust-free, oil-free, and leak-free. Test all joints for leaks before insulating.<\/li>\n<li>Cut insulation to specified size and remove 50 mm of insulation from edges, leaving the facing material flap for overlap at joints.\n<p><div id=\"attachment_22855\" style=\"width: 730px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/3t-insulation.com\/product\/attachment\/duct_technical_2\/\" rel=\"attachment wp-att-22855\"><img decoding=\"async\" aria-describedby=\"caption-attachment-22855\" class=\"lazyload size-full wp-image-22855\" src=\"https:\/\/3t-insulation.com\/wp-content\/uploads\/2022\/05\/duct_technical_2.png\" data-orig-src=\"https:\/\/3t-insulation.com\/wp-content\/uploads\/2022\/05\/duct_technical_2.png\" alt=\"DUCT COVER WITH INSULATION\" width=\"720\" height=\"400\" title=\"|\" srcset=\"data:image\/svg+xml,%3Csvg%20xmlns%3D%27http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%27%20width%3D%27720%27%20height%3D%27400%27%20viewBox%3D%270%200%20720%20400%27%3E%3Crect%20width%3D%27720%27%20height%3D%27400%27%20fill-opacity%3D%220%22%2F%3E%3C%2Fsvg%3E\" data-srcset=\"https:\/\/3t-insulation.com\/wp-content\/uploads\/2022\/05\/duct_technical_2-200x111.png 200w, https:\/\/3t-insulation.com\/wp-content\/uploads\/2022\/05\/duct_technical_2-350x194.png 350w, https:\/\/3t-insulation.com\/wp-content\/uploads\/2022\/05\/duct_technical_2-400x222.png 400w, https:\/\/3t-insulation.com\/wp-content\/uploads\/2022\/05\/duct_technical_2-500x278.png 500w, https:\/\/3t-insulation.com\/wp-content\/uploads\/2022\/05\/duct_technical_2-600x333.png 600w, https:\/\/3t-insulation.com\/wp-content\/uploads\/2022\/05\/duct_technical_2-700x389.png 700w, https:\/\/3t-insulation.com\/wp-content\/uploads\/2022\/05\/duct_technical_2.png 720w\" data-sizes=\"auto\" data-orig-sizes=\"(max-width: 720px) 100vw, 720px\" \/><\/a><p id=\"caption-attachment-22855\" class=\"wp-caption-text\">Glass Wool Duct Insulation Cutting Method<\/p><\/div><\/li>\n<li>Wrap insulation around duct with tight joints, overlap the facing flap, and seal all joints with aluminum foil tape 2.5 inches or wider\n<div class=\"mceTemp\"><\/div>\n<p><div id=\"attachment_22856\" style=\"width: 730px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/3t-insulation.com\/product\/attachment\/duct_technical\/\" rel=\"attachment wp-att-22856\"><img decoding=\"async\" aria-describedby=\"caption-attachment-22856\" class=\"lazyload size-full wp-image-22856\" src=\"https:\/\/3t-insulation.com\/wp-content\/uploads\/2022\/05\/duct_technical.png\" data-orig-src=\"https:\/\/3t-insulation.com\/wp-content\/uploads\/2022\/05\/duct_technical.png\" alt=\"DUCT TECHNICAL\" width=\"720\" height=\"400\" title=\"|\" srcset=\"data:image\/svg+xml,%3Csvg%20xmlns%3D%27http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%27%20width%3D%27720%27%20height%3D%27400%27%20viewBox%3D%270%200%20720%20400%27%3E%3Crect%20width%3D%27720%27%20height%3D%27400%27%20fill-opacity%3D%220%22%2F%3E%3C%2Fsvg%3E\" data-srcset=\"https:\/\/3t-insulation.com\/wp-content\/uploads\/2022\/05\/duct_technical-200x111.png 200w, https:\/\/3t-insulation.com\/wp-content\/uploads\/2022\/05\/duct_technical-350x194.png 350w, https:\/\/3t-insulation.com\/wp-content\/uploads\/2022\/05\/duct_technical-400x222.png 400w, https:\/\/3t-insulation.com\/wp-content\/uploads\/2022\/05\/duct_technical-500x278.png 500w, https:\/\/3t-insulation.com\/wp-content\/uploads\/2022\/05\/duct_technical-600x333.png 600w, https:\/\/3t-insulation.com\/wp-content\/uploads\/2022\/05\/duct_technical-700x389.png 700w, https:\/\/3t-insulation.com\/wp-content\/uploads\/2022\/05\/duct_technical.png 720w\" data-sizes=\"auto\" data-orig-sizes=\"(max-width: 720px) 100vw, 720px\" \/><\/a><p id=\"caption-attachment-22856\" class=\"wp-caption-text\">Glass Wool Duct Insulation Installation<\/p><\/div><\/li>\n<li>For ducts wider than 24 inches, use fasteners to secure insulation to the duct surface, spacing them no more than 18 inches apart on the bottom side<\/li>\n<li>Inspect facing material and seal any leaks, scratches, or tears with aluminum foil tape to prevent moisture and vapor accumulation in the insulation<\/li>\n<\/ol>\n<table style=\"height: 328px;\" width=\"1049\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\">\n<p style=\"text-align: center;\">Standard Thickness<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">Average Installed Thickness<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">Round Duct<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">Square Duct<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">Rectangular Duct<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p style=\"text-align: center;\">1&#8243; (25 mm)<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">3\/4&#8243; (19 mm)<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">P+7&#8243; (178 mm)<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">P+6&#8243; (152 mm)<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">P+5&#8243; (127 mm)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p style=\"text-align: center;\">1-1\/2&#8243; (38 mm)<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">1-1\/8&#8243; (28 mm)<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">P+9-1\/2&#8243; (241 mm)<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">P+8&#8243; (203 mm)<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">P+7&#8243; (178 mm)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p style=\"text-align: center;\">2&#8243; (51 mm)<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">1-1\/2&#8243; (38 mm)<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">P+12&#8243; (305 mm)<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">P+10&#8243; (254 mm)<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">P+8&#8243; (203 mm)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p style=\"text-align: center;\">2.2&#8243; (56 mm)<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">1.65&#8243; (42 mm)<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">P+13&#8243; (330 mm)<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">P+11&#8243; (279 mm)<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">P+8-1\/2&#8243; (279 mm)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p style=\"text-align: center;\">3&#8243; (76 mm)<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">2-1\/4&#8243; (57 mm)<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">P+17&#8243; (432 mm)<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">P+14-1\/2&#8243; (368 mm)<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">P+11-1\/2&#8243; (292 mm)<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"text-align: left;\"><strong>Technical Data Table<\/strong><\/p>\n<table style=\"height: 257px;\" width=\"837\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\">\n<p style=\"text-align: center;\">Features<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">Technical Specifications<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">Test Standard<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p style=\"text-align: center;\">Water Vapor Absorption<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">0.2 % by volume<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">ASTM C1104<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Mold and Fungus Growth<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">Does not promote mold and fungus growth<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">ASTM C665<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Surface Burning on Insulation<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">Flame Spread &lt; \u2264 25<br \/>\n Smoke Develop &lt; \u2264 50<\/p>\n<\/td>\n<td valign=\"top\">\n<p style=\"text-align: center;\">ASTM E84<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>SCG thermal insulation for air conditioning systems, FRK-G model duct insulation with single-sided fire-retardant tri-directional reinforced aluminum foil, tested to BS 476 and ASTM E84 standards<\/p>\n","protected":false},"featured_media":25801,"template":"","meta":[],"product_brand":[506],"product_cat":[647],"product_tag":[],"class_list":{"0":"post-39153","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-scg","7":"product_cat-cold-air-duct-insulation","9":"first","10":"instock","11":"shipping-taxable","12":"product-type-variable"},"_links":{"self":[{"href":"https:\/\/3t-insulation.com\/en\/wp-json\/wp\/v2\/product\/39153","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/3t-insulation.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/3t-insulation.com\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/3t-insulation.com\/en\/wp-json\/wp\/v2\/media\/25801"}],"wp:attachment":[{"href":"https:\/\/3t-insulation.com\/en\/wp-json\/wp\/v2\/media?parent=39153"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/3t-insulation.com\/en\/wp-json\/wp\/v2\/product_brand?post=39153"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/3t-insulation.com\/en\/wp-json\/wp\/v2\/product_cat?post=39153"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/3t-insulation.com\/en\/wp-json\/wp\/v2\/product_tag?post=39153"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}