SCG Glass Wool Insulation for Air Conditioning Systems, Single-sided Foil FRK-G Model

Price Price range: 1,950.00 บาท through 4,900.00 บาท

Product Details

SCG thermal insulation for air conditioning systems, FRK-G model duct insulation with single-sided fire-retardant tri-directional reinforced aluminum foil, tested to BS 476 and ASTM E84 standards

SCG Glass Wool Insulation for Air Conditioning Systems

Duct Insulation Work

Large air conditioning systems consisting of chillers and Air Handling Units (AHU) require galvanized air ducts to distribute cool air to desired points. To maintain air temperature, heat insulation must be installed to prevent cold air leakage. It also provides soundproofing benefits. Typically, glass wool insulation used in air conditioning duct systems has a density of 24 kg/m³, with thickness options of 1 inch (25 mm) or 2 inches (50 mm), depending on requirements and installation space.

Product List

FRK-G

SCG thermal insulation for air conditioning systems, FRK-G model duct insulation with single-sided fire-retardant tri-directional reinforced aluminum foil, tested to BS 476 and ASTM E84 standards

FRKF-G

SCG thermal insulation for air conditioning systems, FRKF-G model duct insulation with double-sided fire-retardant tri-directional reinforced aluminum foil, tested to BS 476 and ASTM E83 standards

Density (kg/m³)

Thickness (mm.)

Size
(W x L)

Thermal Conductivity (K-value)
W/m.K

16

25

1.22 x 30.50

0.038

16

38

1.22 x 30.50

0.038

16

50

1.22 x 15.25

0.035

24

25

1.22 x 30.50

0.035

24

38

1.22 x 15.25

0.035

24

50

1.22 x 15.25

0.035

32

25

1.22 x 15.25

0.033

32

38

1.22 x 15.25

0.033

32

50

1.22 x 15.25

0.033

48

25

1.22 x 7.50

0.033

Installation Guidelines

  1. Duct surfaces must be clean, dry, rust-free, oil-free, and leak-free. Test all joints for leaks before insulating.
  2. Cut insulation to specified size and remove 50 mm of insulation from edges, leaving the facing material flap for overlap at joints.
    DUCT COVER WITH INSULATION

    Glass Wool Duct Insulation Cutting Method

  3. Wrap insulation around duct with tight joints, overlap the facing flap, and seal all joints with aluminum foil tape 2.5 inches or wider
    DUCT TECHNICAL

    Glass Wool Duct Insulation Installation

  4. For ducts wider than 24 inches, use fasteners to secure insulation to the duct surface, spacing them no more than 18 inches apart on the bottom side
  5. Inspect facing material and seal any leaks, scratches, or tears with aluminum foil tape to prevent moisture and vapor accumulation in the insulation

Standard Thickness

Average Installed Thickness

Round Duct

Square Duct

Rectangular Duct

1″ (25 mm)

3/4″ (19 mm)

P+7″ (178 mm)

P+6″ (152 mm)

P+5″ (127 mm)

1-1/2″ (38 mm)

1-1/8″ (28 mm)

P+9-1/2″ (241 mm)

P+8″ (203 mm)

P+7″ (178 mm)

2″ (51 mm)

1-1/2″ (38 mm)

P+12″ (305 mm)

P+10″ (254 mm)

P+8″ (203 mm)

2.2″ (56 mm)

1.65″ (42 mm)

P+13″ (330 mm)

P+11″ (279 mm)

P+8-1/2″ (279 mm)

3″ (76 mm)

2-1/4″ (57 mm)

P+17″ (432 mm)

P+14-1/2″ (368 mm)

P+11-1/2″ (292 mm)

Technical Data Table

Features

Technical Specifications

Test Standard

Water Vapor Absorption

0.2 % by volume

ASTM C1104

Mold and Fungus Growth

Does not promote mold and fungus growth

ASTM C665

Surface Burning on Insulation

Flame Spread < ≤ 25
Smoke Develop < ≤ 50

ASTM E84