SCG Cylence Zoundblock Sound Insulation
Price 2,000.00 บาท
Product Details
SCG Cylence ZoundBlock Sound Insulation is designed for installation in wall frames to prevent external noise from entering our living spaces
Features high sound absorption properties. When sound energy in wave form hits the porous insulation material, friction occurs and the sound energy is converted to heat energy, reducing loud sounds
SCG Cylence ZoundBlock Sound Insulation
SCG Cylence ZoundBlock acoustic material is designed for installation in wall frames to prevent external noise from entering our living spaces
Features high sound absorption properties. When sound energy in wave form hits the porous insulation material, friction occurs and the sound energy is converted to heat energy, reducing loud sounds
Sound Insulation
This reduces sound energy. As we know, sound is energy in the form of vibration and requires a medium to travel. The best sound insulation material is vacuum because it has no medium for sound to pass through. However, producing such materials is difficult
Therefore, for sound insulation, we use methods that reduce sound energy by converting the vibration energy of sound into heat energy instead
Sound Transmission Loss (STL)
Sound Transmission Loss or STL is a measure of a material’s ability to block sound. Simply explained:
If we have a speaker playing loud music in one room and we walk to an adjacent room, we notice the sound becomes quieter. This reduction in sound is called Transmission Loss (TL) measured in decibels (dB). However, TL is measured across multiple sound frequencies
Sound Transmission Class (STC)
In practice, STL values are too complex to use due to multiple frequencies. Sound Transmission Class or STC provides convenience by averaging TL values across the 125 – 4,000 Hz frequency range. Materials with higher STC values provide better sound blocking
SCG Cylence ZoundBlock Sound Insulation Product List
SCG Cylence ZoundBlock Sound Insulation Product Size Table
|
Products |
Thickness (mm.) |
Size (W x L) |
|
ZoundBlock S100 |
100 |
0.60 x 1.20 m 0.40 x 1.20 m |
|
ZoundBlock S060 |
60 |
0.60 x 1.20 m 0.40 x 1.20 m |
|
ZoundBlock S050 |
50 |
0.60 x 1.20 m 0.40 x 1.20 m |
Using Framework with SCG Cylence ZoundBlock Sound Insulation
|
Insulation Thickness (mm.) |
Installation |
Type |
|
100 |
Installation with Wood Framework |
Cylence ZoundBlock acoustic wall panels are rigid gray acoustic panels for sound protection, wrapped with moisture-resistant and sound-blocking materials. Contains water-repellent substances in the insulation core. Can be installed with gypsum wall systems, fiber cement wall systems, lightweight brick wall systems, clay brick wall systems, and other wall systems to enhance sound blocking performance |
|
60 |
Installation with Metal Framework Size C75 | |
|
50 |
Installation with Metal Framework Size C65 |
Sound Insulation Wall Design Table with SCG Sound Insulation for Various Areas
| Building Type |
Design Area (Source) |
Adjacent Area (Receiver) |
Minimum Sound Blocking Value |
| Apartments, Residential Buildings |
Living Room |
Living Room Adjacent to Solid Wall |
STC 48 – 55 |
|
Bathroom Solid Wall |
STC 50 – 57 |
||
|
Bathroom Opening Wall |
STC 45 – 52 |
||
|
Kitchen Solid Wall |
STC 48 – 55 |
||
|
Mechanical Equipment Area |
STC 58 – 65 |
||
|
Exterior Building Area |
STC 37 – 60+ |
||
| Single House |
Living Room |
Adjacent Bedroom |
STC 40 – 48 |
|
Living Room |
STC 42 – 50 |
||
|
Bathroom Not Connected to Bedroom |
STC 45 – 52 |
||
|
Kitchen Solid Wall |
STC 45 – 52 |
||
|
Exterior Building Area |
STC 37 – 60+ |
||
| School Building |
Classroom |
Adjacent Classroom (Teaching Only) |
STC 42 |
|
Adjacent Classroom (Teaching and Seminars) |
STC 48 |
||
|
Laboratory |
STC 48 |
||
|
Corridor or Public Area |
STC 42 |
||
|
Kitchen and Dining Room |
STC 47 |
||
|
Shop |
STC 52+ |
||
|
Recreation Area |
STC 52+ |
||
|
Music Room |
STC 52+ |
||
|
Mechanical Equipment Area |
STC 55+ |
||
|
Bathroom |
STC 47 |
||
|
Exterior Building Area |
STC 37 – 60+ |
||
|
Theater Hall |
Adjacent Theater Hall |
STC 52+ |
|
|
Corridor or Public Area |
STC 52 |
||
|
Practice Room |
STC 52+ |
||
|
Shop |
STC 57 |
||
|
Recreation Room |
STC 57 |
||
|
Laboratory |
STC 52 |
||
|
Bathroom |
STC 52 |
||
|
Mechanical Equipment Area |
STC 58 – 65+ |
||
|
Exterior Building Area |
STC 47+ |
||
|
Music Practice Room |
Adjacent Practice Room |
STC 52+ |
|
|
Corridor or Public Area |
STC 52+ |
||
|
Language Room |
Same as Theater Hall |
||
|
Consultation Room |
Same as Theater, Conference Hall, Recording Studio |
||
| Performance Venue |
Theater, Conference Hall |
Adjacent Performance Venue |
Consult with insulation manufacturer for design and construction recommendations for such conditions |
|
Recording Studio |
Public Corridor Area |
||
|
Recreation Area |
|||
|
Mechanical Equipment Area |
|||
|
Classroom |
|||
|
Laboratory |
|||
|
Shop |
|||
|
Bathroom Area |
|||
|
Exterior Building Area |
|||
| Office Area, Confidential Meeting Room |
Office |
Adjacent Office |
STC 45 |
|
Other General Offices |
STC 45 |
||
|
Corridor |
STC 45 |
||
|
Bathroom and Laundry Room |
STC 47 |
||
|
Exterior Building Area |
STC 37 – 60+ |
||
|
Kitchen and Dining Room |
STC 47 |
||
|
Mechanical Equipment Area |
STC 52 |
||
| General Office Area |
Office |
Other Meeting Rooms |
STC 45 |
|
Adjacent Office |
STC 45 |
||
|
Other General Offices |
STC 45 |
||
|
Corridor |
STC 45 |
||
|
Office and Laundry Room |
STC 47 |
||
|
Exterior Building Area |
STC 37 – 60+ |
||
|
Kitchen and Dining Room |
STC 47 |
||
|
Mechanical Equipment Area |
STC 52+ |
||
| Drafting Room, Bank Office |
Office |
Corridor |
STC 37 |
|
Exterior Building Area |
STC 37 – 60+ |
||
|
Office |
STC 42 |
||
|
Mechanical Equipment Area |
STC 47+ |
||
|
Kitchen and Dining Room |
STC 42 |
||
| Factory Office Area |
Laboratory |
Adjacent Office |
STC 42 |
| Laboratory Requiring Moderate Quiet |
Laboratory |
STC 42+ |
|
|
Bathroom and Laundry Room |
STC 42 |
||
|
Corridor |
STC 37 |
||
|
Exterior Building Area |
STC 37 – 60+ |
||
| Curtain Hotel and City Hotel |
Bedroom |
Adjacent Bedroom |
STC 48+ |
| (Same as Apartment) |
Bathroom Separate from Bedroom |
STC 52+ |
|
|
Living Room Separate from Bedroom |
STC 50+ |
||
|
Dining Area |
STC 50+ |
||
|
Corridor or Public Area |
STC 48+ |
||
|
Mechanical Equipment Area |
STC 52+ |
||
|
Exterior Building Area |
STC 37 – 60+ |
||
| Apartment, Condominium, Residential Building |
Bedroom |
Bedroom Adjacent to Solid Wall |
STC 48 – 55 |
|
Bathroom Solid Wall |
STC 52 – 58 |
||
|
Bathroom Open Wall Connected to Bedroom |
STC 45 – 52 |
||
|
Living Room Solid Wall |
STC 50 – 57 |
||
|
Living Room Open Wall Connected to Bedroom |
STC 42 – 50 |
||
|
Kitchen Solid Wall |
STC 52 – 58 |
||
|
Kitchen Open Wall Connected to Bedroom |
STC 45 – 52 |
||
|
Mechanical Equipment Area |
STC 58 – 65 |
||
|
Balcony Area, Common Area |
STC 48 – 55 |
||
|
Exterior Building Area |
STC 42 – 60+ |