MicroFiber Glass Wool Insulation Roof Thermal Insulation Model ENF
Price 3,160.00 บาท – 6,600.00 บาทPrice range: 3,160.00 บาท through 6,600.00 บาท
Product Details
MicroFiber glass wool insulation Model ENF for roof thermal insulation, surfaced with heat-reflective aluminum foil sheets on 2 sides. Available in long rolls that can be rolled along rafter grooves or across rafters.
Available in densities from 12K – 48K and insulation thickness from 25 mm – 75 mm. The insulation material is yellow in color, non-water absorbent. When water drops on the insulation material, it forms droplets without penetrating the insulation. Water droplets can evaporate naturally when air flows through.
MicroRoof
Micro Roof glass wool insulation is designed for roofing applications to prevent heat from the roof from entering factory buildings. Factory metal sheet roofs reach maximum temperatures of 70°C during lunch breaks, which transfers heat down to the building, resulting in extremely hot working conditions.
Installing roof insulation reduces the temperature transferred from the roof, minimizing it so that people working in the building do not experience excessive heat. In air-conditioned warehouses with cooling systems, installing thermal insulation helps reduce air conditioning workload because less heat is transferred down, and it can retain cool air inside for longer periods.
Thermal Conductivity
For thermal insulation applications, the most important consideration is the thermal conductivity value of the insulation (K-value). Thermal conductivity indicates how well insulation can transfer heat. The higher the thermal conductivity value, the more heat can pass through. Therefore, high thermal conductivity means poor insulation, as we want to prevent heat transfer. Thus, thermal conductivity values closer to 0 indicate better thermal insulation.
MicroFiber glass wool insulation has submitted materials for thermal conductivity testing to ASTM (American Society for Testing and Materials) according to ASTM C518 testing standards to determine the material’s thermal conductivity value.
Moisture Absorption
Moisture absorption of roof insulation is extremely important because roofing applications may develop holes over time as materials wear out and roofs develop leaks, causing rainwater to drip onto the insulation. If the insulation material absorbs water, it will become heavier and water will be more difficult to evaporate.
However, MicroFiber glass wool insulation has been tested for water absorption according to ASTM C411 standard, which tests material water absorption. From these test results, we achieved a water absorption value of < 1%, which is very low. When we test by dropping water onto MicroFiber glass wool insulation, water droplets do not penetrate the insulation material but cluster together as droplets on the insulation surface and naturally evaporate.
Mold Resistance
Roof thermal insulation is installed under roofs where inspection for integrity is quite difficult. If mold or damage occurs, insulation should not promote the growth of organisms like mold or fungi that could affect indoor air quality. MicroFiber glass wool insulation is a product that does not promote mold growth and is not a food source for organisms, so there is no concern about damage from mold or fungi. It can be used with buildings long-term.
Surface Burning Characteristic
According to the 2006 International Building Code (IBC), it specifies that wall surface materials and ceiling materials inside buildings must be classified for surface flame spread according to ASTM E84 standard, with additions by NFPA (National Fire Protection Agency) according to NFPA 101 Life Safety Code standard, which requires classification of wall surface materials and ceiling materials inside buildings as Class A, Class B, Class C tested according to NFPA 255, ASTM E84, or UL 723.
Testing provides two values: Flame-Spread Index (FSI) and Smoke Development Index (SDI), and materials are classified based on these values.
Material Classification Table for Surface Fire Spread According to ASTM E84
|
Flame-Spread Index (FSI) |
Smoke Development Index (SDI) |
|
|
Class 1 or Class A |
0 – 25 |
450 Maximum |
|
Class 2 or Class B |
26 – 75 |
450 Maximum |
|
Class 3 or Class C |
76 – 200 |
450 Maximum |
According to the surface fire classification table per ASTM E84 standard, MicroFiber glass wool insulation is classified as Class 1 or Class A because it has a Flame-Spread Index < 25 and Smoke Development Index < 50.
Installation Methods
1.) Installing insulation in rafter spaces (with wire mesh attached between rafters)
Install insulation along rafter spaces with Wire Mesh or Chicken Wire installed between rafters or under rafters to support the insulation. This can be installed on roofs under new construction.
2.) Installing insulation in rafter spaces (with wire mesh attached on rafters)
Install insulation along rafter spaces with Wire Mesh or Chicken Wire installed on rafters to support the insulation. This can be installed on roofs under new construction.
3.) Installing insulation in rafter spaces (wire tying method)
Install insulation along rafter spaces with wire tied to rafters at approximately 30 cm intervals to support the insulation. This can be installed on roofs under new construction and completed roofs.
4.) Installing insulation across rafters (with wire mesh attached on rafters)
Install insulation across rafter spaces with Wire Mesh or Chicken Wire installed on rafters to support the insulation. This can be installed conveniently and quickly on roofs under new construction.
5.) Installing insulation across rafters (without wire mesh support)
Install insulation across rafters without using Wire Mesh or Chicken Wire on rafters to support insulation. Suitable for roofing with rafter spacing not exceeding 1.5 meters. Can be installed conveniently and quickly on new construction roofs.
6.) Installing insulation by attachment under floor (Concrete Slab)
Attach insulation to concrete slab floor using spindle pins or anchors spaced approximately 20-30 cm apart, and use wire wrapped around anchor heads extending from insulation in diagonal patterns. Drilling and installing anchors must not impact building structure. This can be installed on buildings under new construction and completed buildings.
Product Size Table
MicroRoof Roll Type Size Table
|
Density (Kg/m3) |
Thickness (mm) |
Size (W x L) |
|
12 |
50 |
1.22 x 16.50 |
|
75 |
1.22 x 11.50 |
|
|
16 |
25 |
1.22 x 30.50 |
|
50 |
1.22 x 15.25 |
|
|
75 |
1.22 x 15.25 |
|
|
24 |
25 |
1.22 x 30.50 |
|
50 |
1.22 x 15.25 |
|
|
75 |
1.22 x 15.25 |
|
|
32 |
25 |
1.22 x 15.25 |
|
50 |
1.22 x 15.25 |
|
|
75 |
1.22 x 7.50 |
|
|
48 |
25 |
1.22 x 7.50 |
|
50 |
1.22 x 7.50 |
|
|
75 |
1.22 x 7.50 |
MicroRoof Sheet Type Size Table
|
Density (Kg/m3) |
Thickness (mm) |
Size (W x L) |
|
32 |
25 |
1.22 x 2.44 |
|
50 |
1.22 x 2.44 |
|
|
75 |
1.22 x 2.44 |
|
|
48 |
25 |
1.22 x 2.44 |
|
50 |
1.22 x 2.44 |
|
|
75 |
1.22 x 2.44 |
Technical Data Table
|
Features |
MicroRoof Products |
Test Standard |
||||
|
Density |
12 Kg/m3 |
16 Kg/m3 | 24 Kg/m3 | 32 Kg/m3 |
48 Kg/m3 |
|
|
Thermal Conductivity (W/m.K) |
0.042 |
0.038 | 0.035 | 0.033 |
0.032 |
ASTM C518 |
|
Operating Temperature |
Max Service Temp 233 C |
ASTM C411 |
||||
|
Moisture Absorption |
< 1% at 49 C (95% RH) |
ASTM C1104 |
||||
|
Corrosion |
Does not accelerate |
ASTM C665 |
||||
|
Mold Resistance |
No Growth |
ASTM C665 |
||||
|
Surface Burning |
Flame Spread |
ASTM E84 |
||||
|
Smoke Developed |
||||||
|
Fire Testing |
Class 0 |
BS 476 Part 6 BS 476 Part 7 ASTM 1530-3 |
||||
|
Ignitability Index 0 |
||||||
|
Spread of Flame Index 0 |
||||||
|
Heat Evolved Index 0 |
||||||
|
Smoke Developed Index 1 |
||||||