MaxTape Black Rubber Insulation Joint Tape MaxFlex
Price 150.00 บาท
Product Details
MaxFlex black rubber insulation joint tape MaxTape is used to seal joints between black rubber insulation to prevent air infiltration and condensation.
Size: 50 mm width, 9.1 meters length, 3 mm thickness
MaxFlex FR
Black rubber insulation is suitable for cold applications, with an operating temperature range of -57 to 125 degrees Celsius. It has a very low thermal conductivity, giving it an advantage over other types of insulation for low-temperature applications.
Thermal Conductivity
Thermal conductivity indicates how much heat a material can transmit. A higher value means the material can transfer heat more quickly and efficiently. Therefore, good thermal insulation should have a low thermal conductivity value, ideally close to 0.
MaxFlex FR black rubber insulation has low thermal conductivity, suitable for low-temperature applications. At 0°C, its thermal conductivity is only 0.031 W/m.K, which is very low, allowing it to retain cold within the system effectively and minimize energy loss.
UV Resistance
The properties of MaxFlex FR black rubber, made from EPDM rubber, give it higher UV resistance than other materials. We tested UV resistance with the Department of Science Service using UVB-313 radiation at 60°C for 8 continuous hours. The results showed no changes to the MaxFlex FR insulation.
This ensures that when installed and exposed to sunlight, it can withstand without cracking. However, if MaxFlex FR black rubber insulation is installed outdoors and exposed to sunlight and weather conditions, it should be jacketed to extend the material’s lifespan due to weather and biological factors.
Water Absorption
The water absorption property of materials in insulation applications should be low. In black rubber insulation applications that encounter low temperatures, condensation can easily occur, which can cause pipe corrosion or damage to other materials.
Therefore, black rubber insulation or other types of insulation should not absorb water. The water absorption of MaxFlex FR black rubber insulation is less than 0.05% by volume, which is extremely low – practically non-absorbent.
Fire Performance
Building systems have strict requirements for materials, especially regarding flammability. Black rubber insulation is used in water pipe systems or air conditioning systems, which run throughout the building. If the material attached to the pipes catches fire, it could spread quickly throughout the building.
Insulation in pipe systems or air conditioning systems must therefore be fire-resistant. We have tested the fire resistance of MaxFlex FR black rubber insulation according to many standards including BS 476 Part 7, UL 94, ASTM D635, and it has been confirmed as a non-flammable material. When ignited, the flame will self-extinguish.
Product List
MaxFlex Black Rubber Insulation Tube Table
|
MAXFLEX FR Insulation Tube: 2 Meter/Piece |
|||||||||||||
|
ID of MAXFLEX FR Tube |
Pipe Size: mm. (Inch) |
Product |
|||||||||||
|
mm. |
Inch | Copper Pipe | Steel Pipe | PPR |
PVC |
6 mm. Wall (1/4″) |
9 mm. Wall (3/8″) | 13 mm. Wall (1/2″) | 19 mm. Wall (3/4″) | 25 mm. Wall (1″) | 32 mm. Wall (1-1/4″) | 38 mm. Wall (1-1/2″) |
50 mm. Wall (2″) |
|
6 |
1/4″ | 6 | / | / | / | ||||||||
|
9 |
3/8″ | 9 | / | / | / | / | |||||||
|
13 |
1/2″ | 13 | 6 (1/4″ IPS) | 20 (1/2″) | 6 | / | / | / | / | / | |||
|
16 |
5/8″ | 16 | 9 (3/8″ IPS) | 25 (3/4″) | 9 | / | / | / | / | / | / | / | |
|
19 |
3/4″ | 19 | / | / | / | / | / | / | / |
/ |
|||
|
22 |
7/8″ | 22 | 13 (1/2″ IPS) | 32 (1″) | 13 | / | / | / | / | / | / | / |
/ |
|
25 |
1″ | 19 (3/4″ IPS) | / | / | / | / | / | / |
/ |
||||
|
28 |
1-1/8″ | 28 | 19 | / | / | / | / | / | / |
/ |
|||
|
32 |
1-1/4″ | 40 (1-1/4″) | / | / | / | / | / | / |
/ |
||||
|
35 |
1-3/8″ | 25 (1″ IPS) | 25 | / | / | / | / | / | / |
/ |
|||
|
38 |
1-1/2″ | / | / | / | / | / | / |
/ |
|||||
|
42 |
1-5/8″ | 42 | 32 (1-1/4″ IPS) | 50 (1-1/2″) | 32 | / | / | / | / | / | / |
/ |
|
|
45 |
1-3/4″ | / | / | / | / | / | / |
/ |
|||||
|
48 |
1-7/8″ | 38 (1-1/2″ IPS) | 38 | / | / | / | / | / | / |
/ |
|||
|
51 |
2″ | / | / | / | / | / | / |
/ |
|||||
|
54 |
2-1/8″ | 54 | / | / | / | / | / | / |
/ |
||||
|
57 |
2-1/4″ | / | / | / | / | / | / |
/ |
|||||
|
60 |
2-3/8″ | 51 (2″ IPS) | 51 | / | / | / | / | / | / |
/ |
|||
|
64 |
2-1/2″ | 63 (2″) | / | / | / | / | / |
/ |
|||||
|
67 |
2-5/8″ | 67 | / | / | / | / | / |
/ |
|||||
|
73 |
2-7/8″ | 64 (2-1/2″ IPS) | 64 | / | / | / | / | / |
/ |
||||
|
76 |
3″ | 76 | 75 (2-1/2″) | / | / | / | / | / |
/ |
||||
|
80 |
3-1/8″ | 80 | / | / | / | / | / |
/ |
|||||
|
82 |
3-1/4″ | / | / | / | / | / |
/ |
||||||
|
90 |
3-1/2″ | 76 (3″ IPS) | 90 (3″) | 76 | / | / | / | / | / |
/ |
|||
|
92 |
3-5/8″ | 92 | / | / | / | / | / |
/ |
|||||
|
98 |
3-7/8″ | / | / | / | / | / |
/ |
||||||
|
102 |
4″ | 90 (3-1/2″ IPS) | 90 | / | / | / | / | / |
/ |
||||
|
105 |
4-1/8″ | 105 | / | / | / | / | / |
/ |
|||||
|
115 |
4-1/2″ | 102 (4″ IPS) | 110 (4″) | 102 | / | / | / | / | / |
/ |
|||
|
130 |
5-1/8″ | 130 | 125 (5″) | / | / | / | / | / |
/ |
||||
|
140 |
5-1/2″ | 127 (5″ IPS) | 127 | / | / | / | / | / |
/ |
||||
| 165 | 6-1/2″ | 152 (6″ IPS) | 160 (6″) | 152 | / | / | / | / |
/ |
||||
MaxFlex Black Rubber Insulation Roll Table
|
Thickness (mm.) |
Size (m. x m.) |
Area (sq.m) |
|
3 |
1.22 x 15.00 |
18.3 |
|
6 |
1.22 x 21.9 |
26.7 |
|
9 |
1.22 x 15.2 |
18.5 |
|
13 |
1.22 x 10.9 |
13.4 |
|
16 |
1.22 x 9.7 |
11.8 |
|
19 |
1.22 x 7.0 |
8.5 |
|
25 |
1.22 x 5.4 |
6.7 |
|
32 |
1.22 x 4.0 |
4.9 |
|
38 |
1.22 x 3.0 |
3.7 |
|
50 |
1.22 x 2.4 |
2.9 |
MaxFlex Black Rubber Insulation Sheet Table
|
Thickness (mm.) |
Size (m. x m.) |
|
3 |
1.22 x 0.91 |
|
6 |
1.22 x 0.91 |
|
9 |
1.22 x 0.91 |
|
13 |
1.22 x 0.91 |
|
16 |
1.22 x 0.91 |
|
19 |
1.22 x 0.91 |
|
25 |
1.22 x 0.91 |
|
32 |
1.22 x 0.91 |
|
38 |
1.22 x 0.91 |
|
50 |
1.22 x 0.91 |
Technical Data Table
|
Features |
Maxflex FR |
Test Standard |
| Material |
EPDM Blend with additive |
TGA / DSC |
| Material Structure |
Close Cell / Excellent |
– |
| Density |
3-4 lbs/ft3 (48-96 kg/m3) |
ASTM D1667 |
| Operating Temperature |
-57°C – 125°C |
Maxflex becomes hard at -57°C |
|
-70°F – 257°F |
But can be used even at -200°C |
|
| Maximum Temperature |
Can withstand temperature as high as 125°C |
ASTM C411 |
| Ozone Resistance |
No Crack |
ASTM D1171 |
| UV Resistance |
No Crack |
ASTM G154 |
| Water Absorption |
<≤ 1.5% by Weight <≤ 0.05% by Volume |
ASTM D1056 |
| Water Vapor Transmission Resistance |
Mu > ≥ 12,000 |
ASTM C209 |
| Fungal and Microbial Resistance |
Compliance with requirement |
ASTM E2180, ASTM G21 |
| Dimensional Stability under Heat (% Shrinkage)
At 200 F (7 Days) |
<≤ 3.5% Respectively |
ASTM C534 |
| Fire Performance |
Class V0 |
UL 94 |
|
FM Approved |
FM Approval |
|
|
Self-Extinguishing |
ASTM D635 |
|
|
B2 |
DIN 4102 |
|
|
0, 0, 0, 5 |
AS 1530.3 |
|
|
Compliance with requirement |
NFPA 90A & NFPA 90B |
|
| – Flame Spread / Smoke Developed |
25/50 |
ASTM E84 |
| – Reaction to Fire |
Compliance with EURO Class E |
EN ISO 11925 |
| – Fire Index |
Index 5.3 |
EMPA SWISSI |
| Surface Flame Spread |
Class M1 |
FRANCE AFNOR NF P92 501 |
|
Class 1 |
BS 476 Part 7 |
|
| Material Flame Spread |
Class 0 |
BS 476 Part 6 |
| – Total Index of Performance (I) |
Less than 12 |
|
| – Sub Index (i) |
Less than 6 |
|
| Smoke Toxicity | Satisfies max allowable concentration for the following combustion gases CO, HCl, HF, HBr, HCN, NOx, SO2 |
ISO 5659-2:2017 |
| – Smoke Density |
Dm < ≤ 100 |
|
|
Compliance with requirement |
International Marine Organization (IMO) |
|
| RoHS Test |
Compliance with requirement |
Certain Hazardous Substances in Electrical and Electronic Equipment, 2011/65/EU and its amendment Directive (EU) 2015/863 |
| Nitrosamine Content |
Not detected |
BS EN 12868 |
| Ozone Depleting Substances (ODS) |
Not detected |
USEOA502 1A/8260C |
| – CFCs, HCFCs | ||
| Formaldehyde Content |
Not detected |
ISO 17226-1 |
| Asbestos / Dust & Fiber |
Not detected |
EPA600/R |
| Odor Test at 23°C, 40°C |
Grade 1.5, Grade 2.0 |
FLTM BO 131-03 |
| Corrosion of Copper and Stainless Steel |
Non Corrosive |
DIN 1988 |
| Noise Reduction |
Max. 36.3 dB(A) |
DIN 52219 (19 mm Thickness) |